Fire Alarm System for Aerosol

» PRODUCT » Fire Alarm System for Aerosol

Aerosol Supporting Equipment-Automatic Fire Detection and Alarm System

A qualified control system is the perfect partner for aerosol fire extinguishing systems, and their relationship is like that of a wife and husband.

enquiry
  • Specifications
  • Main Features
  • Application
  • Other Information

The aerosol fire extinguishing device itself is also a device that can automatically detect fires, so for small space fires, the aerosol itself can automatically use its built-in thermal line or glass ball to detect fires, which is very convenient.

But if the protected space is relatively large, then a fire alarm system will need to be used to support it.

Below, we will focus on introducing the specialized aerosol fire alarm and detection system, and their parameters:

FIRE CONTROL PANEL

fire control panel, also named gas extinguishing release control panel, it is the central processing unit or heart of the alarm system, all other fire alarm components include heat detector, smoke detector, manual call point, abort switch etc must be connected to the system through it.

  • Model number: AW-GEC-2169.
  • Panel size: 350*280*112.5 mm.
  • AC input power: 100-200, 50HZ.
  • DC output from the power supply board: 24VDC (24±5) and 5VDC (5±0.1).
  • The voltage for MCU: 5V.
  • Current @ 24VDC from PSE: less than 450mA (standby current).
  • Maximum current from PSE: 3 Ampere (except battery charge current).
  • Battery discharge current: Maximum 3.15 Ampere current limited.
  • Auxiliary power output: 24 VDC, maximum 200mA with current limited.
  • Detector numbers in each zone: 16 pieces.
  • Max detector numbers per CIE: 64 pieces.
  • Zone alarm current: 6 to 27 mA.
  • Communication ports(terminals): 2 wires RS 485 bus systems.
  • EOL resistors for zone input and output: 6.8KΩ/1W.
  • Operating temperature range: -5 to +45℃.
  • Humidity: 5% to 95%, non-condensing.
  • Weight of the panel: 9.9 kilograms with batteries, 8.2 kilograms without batteries.

STROBE AND HORN

Strobe and horn also named strobe sounder,

  • Item: AW-CSS-2166-2.
  • Size: 151*115*51 mm.
  • Working volt and current: DC 12 to 24 V and current less than 60 mA.
  • Flash period: less than 1 seconds.
  • Alarm sound: more than 100 dB at 1 meters.
  • Life span of the flash light: more than 40000 time.
  • Alarm sounder type: Ambulance, Police car, Fire truck.
  • Service life time: 10 years.

CONVENTIONAL SMOKE DETECTOR

  • Item: AW-CSD-381.
  • Specification: 100*100*48 mm.
  • Volt: 12 or 24 Volt.
  • Wiring: the promise of two bus systems zone- and zone+.
  • Relay output: 0.5 A at 24 VDC.
  • Weight: 115 grams.

CONVENTIONAL HEAT DETECTOR

  • Part number: AW-CTD-382.
  • Standby current: less than 20 uA.
  • The maximum alarm current: less than 15 mA.
  • Fix temperature alarm: 57℃, 68 ℃ etc.
  • Working temperature: -10 to +60℃.
  • Relative humidity: 95% non-condensing.

FIRE ALARMS

  • Style number: AW-CBL-2166-A.
  • Diameter: 150*61 mm.
  • Work voltage: 20 to 28 VDC.
  • Work current: maximum 60 mA.
  • Volume: more than 68 dB.
  • Weight: 900 grams.

GAS RELEASE WARNING SIGN

  • Model: AW-GRS2158.
  • Operation volt: DC or AC 24 volt, non-polarized.
  • Working current: less than 70mA under 24 VDC.
  • Flash time: 1.2 to 1.8 seconds.
  • Matching panel: AW-GEC2169 gas fire control panel.

ABOART SWITCH AND MANUAL RELEASE STATION

  • Model: AW-GD210 AND AW-GD202.
  • Dimension:100*100*98 mm.
  • Function: start and abort.

All above mentioned components can form a completely fire alarm and detection systems, and then work together with aerosol systems.

Reference standards: ISO 7240-1:2014(en)

  • This fire alarm system is special designed for gas type suppression generators, including: fm200, novec 1230, aerosol, dry chemical, foam and water mist systems.
  • Each component has specific parameters and specifications, and the components are compatible and cooperate with each other.
  • All components must be connected to the controller, which serves as the central processing unit.
  • All components are with small dimension, able to save installation space as much as possible.
  • Highly integrated system with high tactile sensitivity.
  • The detection components cooperate with each other and do not interfere with each other.
  • The system has a 30 second delay function. Once a fire is detected, it can delay for 30 seconds, during which people can quickly escape.

It can be applied in places where gas fire extinguishing systems can be installed, such as:

  • Computer room.
  • data processing room.
  • high-rise buildings.
  • Historical archives.
  • Closed parking lot.
  • Hotels and restaurants.
  • Power generator room.
  • Genset room.
  • Hazardous Product Room.
  • Wind turbine.
  • Vehicles engine room.
  • Braking zone.
  • Power supply room.
  • Meeting room.
  • Cupboard.
  • Backup generator room.
  • Hydraulic system room.

Each unit of the fire alarm systems has its unique advantages and characteristics, For more detailed information, please contact the supplier to request a PDF format file.

Usually, an aerosol fire extinguishing system project also requires a complete fire alarm and detection system.

Jiangxi Aware Fire Technology Co.,Ltd can provide one-stop service, for the installation and system debugging of fire suppression and fire alarm systems.