Mini Automatic Aerosol Fire Extinguishers

» PRODUCT » Mini Automatic Aerosol Fire Extinguishers

  • Electrical series china supplier minisol aerosol fire extinguishing system

    Electrical series china supplier Minisol aerosol fire extinguishing system is use electrical or electronics trigger and power supply as activation resource to start the aerosol generator, by using electrical trigger of activation mode have the following features:

    • Need power supply of DC 3 to DC 24 voltage and AC 3 to AC 240 voltage.
    • Normally have to work with fire alarm systems.
    • But can standalone work with TAD thermal activation device, where the TAD supply with a small current to start-up the aerosol extinguishing device separately.
    enquiry
    • Specifications
    • Aerosol Features and Characteristics
    • Aerosol Application

    Electrical series of Minisol aerosol fire extinguishing system shows the aerosol generator is with electrical and electric start activation, this activation mode use power supply of AC 3 to 24 volt or DC 3 to 240 volt as power supply resource.

    The electrical series of Minisol aerosol fire extinguishing device and its system have the following basic specifications:

    • Main oxidant: chemical of strontium nitrate.
    • Aerosol compound quality in grams: 30, 60, 100, 150, 200, 250, 300, 500, 750, 1000, 1500, 2000, 2500, 3000.
    • Aerosol compound design density: 100 gram per cubic meters.
    • Protection volume in cubic meter: 0.3, 0.6, 1.0, 1.5, 2, 2.5, 3.0, 5, 7.5, 10.0, 15.0, 20.0, 25.0, 30.0.
    • Safety distance for people: keep more than 1.5 meter far away.
    • Fire extinguishing safety distance: about 0.3 meter.
    • Extinguishing time: no more than 30 seconds.
    • Product size: Variety size, refer to our “Technical data sheet“.
    • Product weight: Variety, refer to our “technical data sheet”.
    • Life span of the product: 10 years.
    • Fire Extinguishing class and type: Class A,Class B, Class C, Class E and even Class F.
    • Temperature of nozzle in the bottom after discharging: no more than 200°C in about 5 millimeter distance form the nozzle.
    • Cylinder Temperature after discharging: no more than 100°C.
    • Cylinder material: 304 stainless steel.
    • Electrical trigger material: aluminium alloy activation head (aviation plugs) and copper cable.
    • Working temperature: under -40 and above +70 degree Celsius.
    • Working voltage: DC 3 to 24 voltage for direct current and AC 3 to 240 volt for alternating current.
    • Maximum safety current: less than 150 milliampere per 5 minutes.
    • Minimum activation current: more than 250 milliampere per 5 milliseconds.
    • Working humidity: no more than 95%.
    • Installation mode of aerosol device: with “L” shape of installation bracket with screws, or with magnetic with 3M brand of glue.
    • Multiple device wire connection mode: with series wire connection.

    Electrical trigger activation of aerosol device and its system is have the followings features and characteristics:

    • require to work with outer power supply as a power source. or work with a standalone battery power supply, or work with TAD thermal activation device.
    • Aerosol compound is highly effective compound, its design density is 100 gram per cubic meters.
    • Non-toxic.
    • Non corrosive
    • Non conductive.
    • Non-pressurized.
    • Not have residue after discharging.
    • easy to install, don't need vessels, no need piping and manifold, or expensive installation manpower.
    • Environmentally friendly with zero value of ozone layer depletion Potential, zero value of global warning potential, low value of Atmospheric Life.
    • Will not harm any electronic equipment or magnetic tape.
    • Low in maintenance.
    • Long life span, as long as 10 more years.
    • Suitable for any enclosed facilities and local spaces.
    • Suitable for Class A,B,C,E fire hazard and even Class E fire.
    • Compact-up to a 90% reduction in space and weight requirements.
    • Most importantly, it belongs to gas fire suppression system, but much more compact and space saving than other gas systems, such as carbon dioxide system, FM200 system and IG541 system etc.
    • Many international standard to obey, including NFPA 2010-Standard for fixed aerosol fire-extinguishing systems; ISO 15779:2011-condensed aerosol fire extinguishing systems - requirements and test methods for components and test methods for components and system design, installation and maintenance - General requirements; IMO/MSC 1270 - Revised guidelines for the approval of fixed aerosol fire-extinguishing systems equivalent to fixed gas fire-extinguishing systems, as referred to SOLAS 74, for machinery spaces; UL 2775 - Standard for fixed condensed aerosol extinguishing system units; EN15276 - Fixed firefighting systems - condensed aerosol extinguishing systems - Part 1: requirements and test methods for components, part 2: design, installation and maintenance; China GA499.1-2010 - Aerosol fire extinguishing system - Part 1: condensed aerosol fire extinguishing device (Remark: if need GA499.1-2010 documents please ask us for help).

     

    Electronics trigger/electrical activation of aerosol extinguishing system device are widely use in variety of industries. hereby we list out some industries that it can apply in but not limits to the following:

    • Power generator room and power distribution room.
    • Computer server room and rack.
    • Library, Museum, archives space.
    • Data center room.
    • Pumping stations.
    • Printing rooms.
    • Substations.
    • Vehicles such as railway locomotive, bus vehicles, coach, car engine etc.
    • Manufacturer's workshop and factory.
    • Offshore drilling plant room.
    • Cable Well and Cable Trays and electric cabinets.
    • Diesel generator room.
    • Switch gear room.
    • Wind turbine nacelles room and its power room.
    • Lead acid battery room or Lithium ion room.
    • Electric machine room.
    • Gas turbine enclosures.
    • More other facilities that also will require to install electrical activation of aerosol fire extinguishing device.