An aerosol suppression system is a good solution for wind turbines in the new energy industry, many countries have applied this fire suppression technology in the wind power industry, and the aerosol technology is very mature now.
Modern wind turbines originated in Denmark in the late 19th century, the Danes first invented the first wind turbine, and the United States designed and manufactured a 1250kw wind turbine in 1941.
At present the famous wind power producers are Vestas in Denmark, Gamesa in Spain, GE Wind in the USA, Suzlon in India, and Gnercon in Germany. In the wind industry, wind turbines are becoming larger and larger, and the unit capacity of wind turbines is continuously increasing, gradually becoming the most mature and large-scale technology among renewable energy in the world.
According to estimates, globally available wind energy resources are 20 billion kilowatts, about 10 times more than the available water resources.
With the exhaustion of traditional non-renewable energy and the development of the international new energy industry, the use of new energy is becoming the trend, wind power has become the most complete technology.
In recent years, more and more fires have occurred on wind power, and the safe operation of wind power systems is increasingly valued by the government and by the wind power regulatory department.
Fire will not only cause devastating damage to the wind power systems but also may cause environmental damage and personnel death and then bring greater social risk, So protecting the wind turbines and reducing damage is one of the necessary work for supporting and protecting the development of wind power industry.
The main causes of the wind turbine fire are as below:
Risk parts: Lubrication and cooling system, gearwheel box, brake systems, transmission cable, cabin base, control cabinet, grid cabinet, Converter cabinet.
The causes of fire in this location possibly are high-temperature operation, poor ventilation, Bad quality of electrical components, overheating or aging of the components, wheel oil leakage, brake adjustment, or bad weather.
Risk parts: blade, Hub lubrication system, pitch motor and its control system, battery cabinet, and Capacitor cabinet.
The causes of fire in this location possibly are: the blade was struck by thunderbolt lightning, Pitch motor overload operation, bad quality of pitch control system components, aging of electric components, capacitor short circuit, and so on.
Risk parts: transmission control cable, Frequency conversion cabinet, tower base control cabinet.
The causes of fire in this location possibly are the control cabinet space being small, poor ventilation, overheating and aging of electrical cabinet, poor cable performance, etc.
wind turbine cabin needs to be protected by a total flooding solution, on the top ceiling of the cabin we installed the THERMAL ACTIVATION DEVICE with a rated temperature of 93℃, together with a heat detector and smoke detector, they a fire detection elements in the cabin, and in a suitable locations also install a fire extinguishing total control device, better inside cabin or in the bottom of tower; in a suitable locations inside the cabin install aerosol fire extinguishing device with larger capacity.
When a thermal activation device, heat detector, or smoke detector detects a fire, it sends a composite signal to the fire extinguishing total control device, the total control device sends out a normal-open signal, and then the control room can display fire alarm information in the computer, at this time it can be manual intervention when the fire alarm touches its highest level, the fire extinguishing control device can start-up the aerosol fire extinguishing device automatically. When people find fire occurs directly by eye-sight, he/she can stop the wind turbine manually, when cabin room temperature arrives at 93℃, the thermal activation device begins to work, and the aerosol extinguishing device begins to work and suppress the fire rapidly, after aerosol discharging the wind turbine can work as normal.
In every electrical cabinet, we install one thermal activation device and aerosol device with electrical activation and thermal cord activation; when the temperature in the cabinet rises to a rated temperature of 93℃, the aerosol device will be started by the thermal activation device; and when in the cabinet there is fire flame and ignite the thermal cord, the thermal cord will also start-up the aerosol device automatically and suppress fire quickly.
When aerosol is released it will cover all the cabinet space, so the fire will be suppressed rapidly, after aerosol extinguishing the wind turbine will work as normal.
After we describe our solution you will ask why aerosol can be able to apply in wind turbines, it is decided by its characteristics and features.
Aerosol extinguishing devices have characteristics and features:
One big wind turbine equipment costs millions of dollars, this precious equipment once a fire is knocked down, with the development of fire technology, aerosol suppression device, and its relative accessories will help stop a fire occurring in the wind turbine.

contact us via info@aerosolfire.com
For more details about our aerosol fire suppression systems please feel free to reach us directly, one of our sales experts or technical specialists will respond to the inquiry.